WaterCompared

Water report · not indexed

What is in the water at 02777

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

SOMERSET WATER DEPARTMENT

PWSID MA4273000 · MA · serves 18,303 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

9 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 2950 · began 2021-10-01
  • MCL · contaminant code 2950 · began 2018-01-01
  • MCL · contaminant code 2950 · began 2019-04-01
  • MCL · contaminant code 2950 · began 2019-07-01
  • MCL · contaminant code 2950 · began 2019-10-01
  • MCL · contaminant code 2950 · began 2020-01-01
  • MCL · contaminant code 2950 · began 2020-07-01
  • MCL · contaminant code 2950 · began 2020-10-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

SWANSEA WATER DISTRICT

PWSID MA4292000 · MA · serves 17,375 people

PFAS and lithium

6 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 13 samples.

CompoundHighest detectedSamplesMost recent
PFBA0.011 µg/L27/20/2023
PFHxS0.0077 µg/L28/5/2024
PFOA0.0051 µg/L37/20/2023
PFPeA0.0049 µg/L27/20/2023
PFHxA0.004 µg/L17/20/2023
PFBS0.0035 µg/L38/5/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

10 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 2950 · began 2019-07-01
  • MCL · contaminant code 2950 · began 2019-10-01
  • MCL · contaminant code 2950 · began 2020-01-01
  • MCL · contaminant code 2950 · began 2016-10-01
  • MCL · contaminant code 2950 · began 2017-01-01
  • TT · contaminant code 0200 · began 2017-05-01
  • MCL · contaminant code 2950 · began 2018-07-01
  • MCL · contaminant code 2950 · began 2018-10-01

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.