WaterCompared

Water report · not indexed

What is in the water at 07719

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

BELMAR WATER DEPT

PWSID NJ1306001 · NJ · serves 20,000 people

PFAS and lithium

3 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 7 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0043 µg/L310/9/2024
PFPeA0.0037 µg/L210/7/2025
PFHxA0.0032 µg/L210/7/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

WALL TWP WATER DEPT

PWSID NJ1352003 · NJ · serves 26,000 people

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 20 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0066 µg/L69/19/2023
PFOS0.005 µg/L49/19/2023
PFHxA0.0039 µg/L69/19/2023
PFPeA0.0038 µg/L49/19/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 55 mg/L as CaCO₃, measured at 2 stations serving this system across 14 results, 2015-07-06 to 2022-09-20. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.