What is in the water at 15214

3 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

PITTSBURGH WATER & SEWER AUTH

PWSID PA5020038 · PA · serves 520,000 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 301 mg/L as CaCO₃, measured at 7 stations serving this system across 13 results, 2021-05-04 to 2025-05-28. Measured in the water source and distribution area, not at a tap, and not in your home.

WEST VIEW WATER AUTHORITY

PWSID PA5020043 · PA · serves 200,000 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 144 mg/L as CaCO₃, measured at 13 stations serving this system across 83 results, 2016-06-16 to 2025-05-07. Measured in the water source and distribution area, not at a tap, and not in your home.

RESERVE TWP WATER DEPT

PWSID PA5020047 · PA · serves 3,204 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.