6 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

LOWER BUCKS CO JOINT MUN AUTH

PWSID PA1090026 · PA · serves 63,007 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

NEWTOWN ARTESIAN WATER CO

PWSID PA1090043 · PA · serves 38,500 people

PFAS and lithium

6 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 29 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.012 µg/L67/17/2024
PFOS0.0079 µg/L57/17/2024
PFBS0.007 µg/L47/17/2024
PFHxA0.0059 µg/L57/17/2024
PFPeA0.0056 µg/L57/17/2024
PFHpA0.004 µg/L47/17/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 2 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

PA AMERICAN WATER CO YARDLEY

PWSID PA1090074 · PA · serves 33,171 people

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 22 samples.

CompoundHighest detectedSamplesMost recent
PFOA0.0097 µg/L48/13/2024
PFOS0.0061 µg/L48/13/2024
PFBA0.0054 µg/L18/13/2024
PFPeA0.0051 µg/L48/13/2024
PFBS0.0048 µg/L48/13/2024
PFHxA0.0048 µg/L48/13/2024
PFHpA0.003 µg/L18/13/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 63 mg/L as CaCO₃, measured at 3 stations serving this system across 6 results, 2025-03-03 to 2025-05-20. Measured in the water source and distribution area, not at a tap, and not in your home.

AQUA PA BENSALEM

PWSID PA1090078 · PA · serves 59,001 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 33 samples.

CompoundHighest detectedSamplesMost recent
PFPeA0.016 µg/L69/30/2024
PFHxA0.012 µg/L69/30/2024
PFOA0.008 µg/L49/30/2024
PFBA0.0076 µg/L49/30/2024
PFOS0.0075 µg/L37/29/2024
PFBS0.0054 µg/L49/30/2024
PFHxS0.0052 µg/L49/30/2024
PFHpA0.0034 µg/L27/29/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

BCWSA MAIN LOWER SOUTH

PWSID PA1090079 · PA · serves 52,621 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 39 samples.

CompoundHighest detectedSamplesMost recent
PFPeA0.019 µg/L78/7/2024
PFHxA0.012 µg/L78/7/2024
PFBA0.0075 µg/L48/7/2024
PFOA0.0073 µg/L68/7/2024
PFOS0.0069 µg/L48/7/2024
PFBS0.0056 µg/L48/7/2024
PFHxS0.0048 µg/L48/7/2024
PFHpA0.0032 µg/L38/7/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 138 mg/L as CaCO₃, measured at 2 stations serving this system across 174 results, 2015-01-22 to 2026-03-18. Measured in the water source and distribution area, not at a tap, and not in your home.

AQUA PA MAIN SYSTEM

PWSID PA1460073 · PA · serves 822,600 people

PFAS and lithium

10 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 227 samples.

CompoundHighest detectedSamplesMost recent
lithium16 µg/L28/12/2024
PFPeA0.022 µg/L439/25/2024
PFHxA0.017 µg/L429/25/2024
PFOA0.013 µg/L359/10/2024
PFNA0.012 µg/L78/20/2024
PFBA0.01 µg/L208/7/2024
PFBS0.0095 µg/L359/25/2024
PFOS0.0092 µg/L169/10/2024
PFHxS0.0077 µg/L119/10/2024
PFHpA0.0069 µg/L168/20/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 188 mg/L as CaCO₃, measured at 14 stations serving this system across 60 results, 2015-02-05 to 2023-10-25. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.