WaterCompared

Water report · not indexed

What is in the water at 19720

4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

ARTESIAN WATER COMPANY

PWSID DE0000552 · DE · serves 231,114 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 76 samples.

CompoundHighest detectedSamplesMost recent
PFPeA0.11 µg/L186/4/2024
PFBA0.079 µg/L216/4/2024
PFHxA0.072 µg/L146/4/2024
PFOA0.023 µg/L86/4/2024
PFHpA0.019 µg/L55/8/2024
PFHxS0.0089 µg/L35/6/2024
PFBS0.0087 µg/L55/6/2024
PFOS0.006 µg/L25/6/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

We do not state a hardness for any system, and this is why. Hardness here would come from environmental monitoring stations that happen to sit inside your water system’s service area. We checked that method against the figures twenty large utilities publish about their own supply: it agreed with the utility fewer than half the time, and where it was wrong it usually read HIGH. Cities supplied from a distant watershed came off worst, because the stations end up sampling local groundwater nobody drinks. We are paid a referral fee when somebody asks for an installer, so a number that overstates hardness is the last error we are willing to publish. Your utility publishes its own hardness in its annual water quality report, and that figure is the one to trust.

VEOLIA WATER DELAWARE, INC

PWSID DE0000564 · DE · serves 100,495 people

PFAS and lithium

9 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 59 samples.

CompoundHighest detectedSamplesMost recent
PFBA0.041 µg/L85/10/2023
PFPeA0.032 µg/L85/10/2023
PFHxA0.032 µg/L85/10/2023
PFHpA0.028 µg/L85/10/2023
PFOA0.024 µg/L85/10/2023
PFNA0.012 µg/L85/10/2023
PFDA0.0047 µg/L312/11/2023
PFUnA0.0038 µg/L212/11/2023
PFBS0.0037 µg/L65/10/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

We do not state a hardness for any system, and this is why. Hardness here would come from environmental monitoring stations that happen to sit inside your water system’s service area. We checked that method against the figures twenty large utilities publish about their own supply: it agreed with the utility fewer than half the time, and where it was wrong it usually read HIGH. Cities supplied from a distant watershed came off worst, because the stations end up sampling local groundwater nobody drinks. We are paid a referral fee when somebody asks for an installer, so a number that overstates hardness is the last error we are willing to publish. Your utility publishes its own hardness in its annual water quality report, and that figure is the one to trust.

MUNICIPAL SERVICES COMMISSION

PWSID DE0000634 · DE · serves 5,549 people · service area inferred by a model, not supplied by the state

PFAS and lithium

2 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 2 samples.

CompoundHighest detectedSamplesMost recent
PFBA0.15 µg/L13/8/2023
PFPeA0.12 µg/L13/8/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

We do not state a hardness for any system, and this is why. Hardness here would come from environmental monitoring stations that happen to sit inside your water system’s service area. We checked that method against the figures twenty large utilities publish about their own supply: it agreed with the utility fewer than half the time, and where it was wrong it usually read HIGH. Cities supplied from a distant watershed came off worst, because the stations end up sampling local groundwater nobody drinks. We are paid a referral fee when somebody asks for an installer, so a number that overstates hardness is the last error we are willing to publish. Your utility publishes its own hardness in its annual water quality report, and that figure is the one to trust.

WILMINGTON WATER DEPARTMENT

PWSID DE0000663 · DE · serves 107,976 people

PFAS and lithium

6 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 40 samples.

CompoundHighest detectedSamplesMost recent
PFPeA0.032 µg/L88/9/2023
PFHxA0.021 µg/L88/9/2023
PFBA0.014 µg/L78/9/2023
PFOA0.0099 µg/L88/9/2023
PFHpA0.0084 µg/L58/9/2023
PFBS0.0036 µg/L48/9/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

We do not state a hardness for any system, and this is why. Hardness here would come from environmental monitoring stations that happen to sit inside your water system’s service area. We checked that method against the figures twenty large utilities publish about their own supply: it agreed with the utility fewer than half the time, and where it was wrong it usually read HIGH. Cities supplied from a distant watershed came off worst, because the stations end up sampling local groundwater nobody drinks. We are paid a referral fee when somebody asks for an installer, so a number that overstates hardness is the last error we are willing to publish. Your utility publishes its own hardness in its annual water quality report, and that figure is the one to trust.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 1 of 4 service areas here are modelled.