WaterCompared

Water report · not indexed

What is in the water at 19901

4 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

GARRISON LAKE PUMP DISTRICT

PWSID DE0000004 · DE · serves 13,467 people · service area inferred by a model, not supplied by the state

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 4 samples.

CompoundHighest detectedSamplesMost recent
lithium17 µg/L48/5/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

CAMDEN PUMP DISTRICT

PWSID DE0000124 · DE

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 9 samples.

CompoundHighest detectedSamplesMost recent
lithium17 µg/L97/7/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

CAMDEN WYOMING SEWER AND WATER AUTHORITY

PWSID DE0000563 · DE

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 6 samples.

CompoundHighest detectedSamplesMost recent
lithium22 µg/L68/4/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

DOVER WATER DEPARTMENT

PWSID DE0000571 · DE · serves 39,491 people · service area inferred by a model, not supplied by the state

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 30 samples.

CompoundHighest detectedSamplesMost recent
lithium37 µg/L309/19/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

1 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 1032 · began 2023-02-02

Hardness

Median hardness 60 mg/L as CaCO₃, measured at 5 stations serving this system across 162 results, 2021-08-10 to 2025-05-13. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 2 of 4 service areas here are modelled.