WaterCompared

Water report · not indexed

What is in the water at 30728

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

CHATTOOGA COUNTY

PWSID GA0550000 · GA · serves 7,800 people · service area inferred by a model, not supplied by the state

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 40 samples.

CompoundHighest detectedSamplesMost recent
PFBS0.15 µg/L108/14/2024
PFOA0.02 µg/L68/14/2024
PFPeA0.017 µg/L68/14/2024
PFHxA0.014 µg/L48/14/2024
PFHpA0.0079 µg/L48/14/2024
PFBA0.0073 µg/L28/14/2024
PFOS0.0065 µg/L88/14/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 10 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

LAFAYETTE

PWSID GA2950002 · GA · serves 18,177 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 38 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.056 µg/L36/4/2025
PFBS0.044 µg/L169/15/2025
PFOA0.031 µg/L79/15/2025
PFPeA0.0092 µg/L49/15/2025
PFHxA0.008 µg/L36/4/2025
PFHpA0.0076 µg/L26/4/2025
PFHxS0.0052 µg/L26/4/2025
PFDA0.003 µg/L14/16/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 140 mg/L as CaCO₃, measured at 3 stations serving this system across 19 results, 2022-06-16 to 2024-12-03. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 1 of 2 service areas here are modelled.