Water report · not indexed
What is in the water at 30906
One public water system serves this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.
AUGUSTA-RICHMOND CO WS
PWSID GA2450000 · GA · serves 204,000 people · service area inferred by a model, not supplied by the state
PFAS and lithium
7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 18 samples.
| Compound | Highest detected | Samples | Most recent |
|---|---|---|---|
| PFHxS | 0.051 µg/L | 4 | 6/29/2023 |
| PFOS | 0.051 µg/L | 4 | 6/29/2023 |
| PFOA | 0.03 µg/L | 2 | 6/22/2023 |
| PFHxA | 0.009 µg/L | 2 | 6/22/2023 |
| PFBS | 0.0059 µg/L | 2 | 6/22/2023 |
| PFPeS | 0.0054 µg/L | 2 | 6/22/2023 |
| PFPeA | 0.003 µg/L | 2 | 9/6/2023 |
A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.
Health-based violations
1 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.
- TT · contaminant code · began 2016-02-09
Hardness
We do not state a hardness for any system, and this is why. Hardness here would come from environmental monitoring stations that happen to sit inside your water system’s service area. We checked that method against the figures twenty large utilities publish about their own supply: it agreed with the utility fewer than half the time, and where it was wrong it usually read HIGH. Cities supplied from a distant watershed came off worst, because the stations end up sampling local groundwater nobody drinks. We are paid a referral fee when somebody asks for an installer, so a number that overstates hardness is the last error we are willing to publish. Your utility publishes its own hardness in its annual water quality report, and that figure is the one to trust.
What this report cannot tell you
Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.
Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 1 of 1 service areas here are modelled.