WaterCompared

Water report · not indexed

What is in the water at 33435

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

BOYNTON BEACH PWS

PWSID FL4500145 · FL · serves 112,000 people

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 17 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.026 µg/L23/5/2024
PFOA0.0087 µg/L23/5/2024
PFBS0.0081 µg/L23/5/2024
PFPeA0.0081 µg/L33/5/2024
PFHxS0.007 µg/L23/5/2024
PFBA0.0064 µg/L33/5/2024
PFHxA0.0056 µg/L33/5/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 4 station(s), 4 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

PALM BEACH COUNTY WATER UTILITIES

PWSID FL4504393 · FL · serves 597,649 people

PFAS and lithium

9 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 28 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.02 µg/L48/8/2025
6:2 FTS0.013 µg/L111/6/2024
PFOA0.009 µg/L48/8/2025
PFPeA0.0077 µg/L48/8/2025
PFHxA0.0065 µg/L48/8/2025
PFHxS0.0064 µg/L48/8/2025
PFBS0.0061 µg/L48/8/2025
PFBA0.005 µg/L18/8/2025
PFHpA0.0031 µg/L28/8/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 294 mg/L as CaCO₃, measured at 8 stations serving this system across 8 results, 2016-02-11 to 2019-11-18. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.