2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

HARRISON CO WATER ASSOC

PWSID KY0490179 · KY · serves 16,736 people

PFAS and lithium

7 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 11 samples.

CompoundHighest detectedSamplesMost recent
PFOS0.048 µg/L29/26/2024
PFHxS0.015 µg/L29/26/2024
PFPeA0.013 µg/L29/26/2024
PFHxA0.0089 µg/L29/26/2024
PFBA0.0079 µg/L19/26/2024
PFHpA0.0047 µg/L19/26/2024
PFBS0.0042 µg/L19/26/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

EAST PENDLETON WATER DISTRICT

PWSID KY0960112 · KY · serves 5,515 people

PFAS and lithium

8 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 15 samples.

CompoundHighest detectedSamplesMost recent
PFPeA0.019 µg/L39/26/2023
PFHpA0.014 µg/L39/26/2023
PFHxA0.012 µg/L29/11/2024
6:2 FTS0.0067 µg/L23/21/2023
PFBA0.0062 µg/L110/11/2023
PFHxS0.0056 µg/L23/21/2023
PFOA0.0041 µg/L19/26/2023
PFBS0.0031 µg/L112/12/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.