WaterCompared

Water report · not indexed

What is in the water at 53072

3 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

PEWAUKEE CITY WATER AND SEWER UTILITY

PWSID WI2680214 · WI · serves 8,671 people · service area inferred by a model, not supplied by the state

PFAS and lithium

11 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 45 samples.

CompoundHighest detectedSamplesMost recent
lithium11 µg/L46/24/2024
PFHxS0.069 µg/L66/24/2024
PFHxA0.04 µg/L56/24/2024
6:2 FTS0.035 µg/L46/24/2024
PFBS0.027 µg/L46/24/2024
PFPeA0.024 µg/L66/24/2024
PFPeS0.021 µg/L46/24/2024
PFBA0.013 µg/L26/24/2024
PFOS0.012 µg/L46/24/2024
PFOA0.0085 µg/L36/24/2024
PFHpA0.008 µg/L36/24/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

11 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 4010 · began 2019-07-01
  • MCL · contaminant code 4000 · began 2023-10-01
  • MCL · contaminant code 4000 · began 2024-01-01
  • MCL · contaminant code 4000 · began 2024-04-01
  • MCL · contaminant code 4000 · began 2024-07-01
  • MCL · contaminant code 4000 · began 2024-10-01
  • MCL · contaminant code 4000 · began 2025-01-01
  • MCL · contaminant code 4000 · began 2025-04-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

PEWAUKEE VILLAGE WATERWORKS

PWSID WI2680229 · WI · serves 8,166 people · service area inferred by a model, not supplied by the state

PFAS and lithium

2 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 2 samples.

CompoundHighest detectedSamplesMost recent
PFBA0.008 µg/L112/9/2025
PFPeA0.0054 µg/L112/9/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

22 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 4000 · began 2021-07-01
  • MCL · contaminant code 4000 · began 2021-10-01
  • MCL · contaminant code 4000 · began 2022-01-01
  • MCL · contaminant code 4000 · began 2022-04-01
  • MCL · contaminant code 4000 · began 2022-07-01
  • MCL · contaminant code 4000 · began 2022-10-01
  • MCL · contaminant code 4000 · began 2023-04-01
  • MCL · contaminant code 4000 · began 2023-07-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

BROOKFIELD WATER UTILITY

PWSID WI2680253 · WI · serves 29,070 people · service area inferred by a model, not supplied by the state

PFAS and lithium

5 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 33 samples.

CompoundHighest detectedSamplesMost recent
lithium14 µg/L207/27/2023
PFBS0.0047 µg/L47/19/2023
PFPeA0.0044 µg/L67/19/2023
PFHxA0.0033 µg/L11/23/2024
PFHxS0.0032 µg/L27/19/2023

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

1 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 4000 · began 2026-01-01

Hardness

Too few readings to state a hardness. 1 station(s), 1 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 3 of 3 service areas here are modelled.