WaterCompared

Water report · not indexed

What is in the water at 72501

2 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

BATESVILLE WATER UTILITIES

PWSID AR0000250 · AR · serves 10,177 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Too few readings to state a hardness. 1 station(s), 24 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

SOUTHSIDE PUB WATER AUTHORITY

PWSID AR0000254 · AR · serves 9,108 people

PFAS and lithium

Sampled, nothing detected. Tested for 30 compounds under UCMR 5 with none found at or above its reporting limit. A reporting limit is the lowest concentration the method can measure, so this means “below that” rather than “zero”.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

Median hardness 36 mg/L as CaCO₃, measured at 3 stations serving this system across 21 results, 2015-04-27 to 2016-04-25. Measured in the water source and distribution area, not at a tap, and not in your home.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01.