WaterCompared

Water report · not indexed

What is in the water at 81067

3 public water systems serve this ZIP code in the federal records. Everything below comes from EPA monitoring data, and everything missing is named.

PATTERSON VALLEY WC

PWSID CO0145540 · CO

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 2 samples.

CompoundHighest detectedSamplesMost recent
lithium310 µg/L29/9/2024

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

72 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 4000 · began 2016-01-01
  • MCL · contaminant code 4010 · began 2016-01-01
  • MCL · contaminant code 4010 · began 2017-01-01
  • MCL · contaminant code 4000 · began 2017-01-01
  • MCL · contaminant code 4000 · began 2018-01-01
  • MCL · contaminant code 4000 · began 2018-04-01
  • MCL · contaminant code 4010 · began 2018-01-01
  • MCL · contaminant code 4010 · began 2018-04-01

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

ROCKY FORD CITY OF

PWSID CO0145600 · CO

PFAS and lithium

4 compounds detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 7 samples.

CompoundHighest detectedSamplesMost recent
lithium48 µg/L29/9/2025
PFBS0.0085 µg/L29/9/2025
PFHxS0.006 µg/L29/9/2025
PFOS0.0041 µg/L19/9/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

No open health-based violation on record. This covers MCL, treatment technique and MRDL violations in SDWIS that have not been returned to compliance. It excludes monitoring and reporting violations, which are the large majority nationally, so this is not “no violations”, and SDWIS completeness varies by state.

Hardness

No hardness measurement. Hardness is measured at environmental monitoring stations, and none fell inside this system’s service area. That is a gap in where monitoring happens, not a finding about the water.

NORTH HOLBROOK WC

PWSID CO0145630 · CO · serves 58 people · service area inferred by a model, not supplied by the state

PFAS and lithium

1 compound detected at or above the reporting limit under EPA’s UCMR 5 monitoring, across 2 samples.

CompoundHighest detectedSamplesMost recent
lithium180 µg/L28/4/2025

A detection is a measurement, not a violation and not a health finding. EPA states that UCMR 5 results do not indicate compliance or non-compliance with any limit.

Health-based violations

35 open health-based violation(s) recorded in SDWIS and not yet returned to compliance.

  • MCL · contaminant code 4010 · began 2016-01-01
  • MCL · contaminant code 4010 · began 2017-01-01
  • MCL · contaminant code 4010 · began 2018-01-01
  • MCL · contaminant code 4010 · began 2018-04-01
  • MCL · contaminant code 4010 · began 2018-10-01
  • MCL · contaminant code 4010 · began 2018-07-01
  • MCL · contaminant code 4010 · began 2019-01-01
  • MCL · contaminant code 4010 · began 2019-04-01

Hardness

Too few readings to state a hardness. 2 station(s), 3 result(s). Below two stations and five results this page will not state a number: a median of two readings from one creek is not your water.

What this report cannot tell you

Every figure describes water at a sampling point: a treatment plant, an entry point to the distribution system, or a monitoring station. None of it describes water arriving at your tap. Plumbing between the two can add lead and copper, and if your home was built before 1986 a test kit tells you something no federal dataset can.

Sources: EPA UCMR 5 occurrence (final release, frozen July 2026) · EPA SDWIS health-based violations · USGS and state monitoring via the Water Quality Portal · EPA Public Water System Service Area Boundaries v3. Compiled 2026-09-01 · 1 of 3 service areas here are modelled.